MAC Systems (Monitoring, Alarm & Control)
|
Davicom MAC - Monitoring, Alarm and Control for your remote sites
The Davicom MAC is designed to meet the requirements of the broadcasting and wireless telecommunications industries. These best-in-class, stand-alone monitoring and control units interface easily with virtually any type of remote site equipment and sensors, which ensures maximum flexibility and expandability. Reliable and comprehensive remote monitoring and control technology is essential for stations with remote transmitter sites. Although having a main street studio and a mountaintop transmitter can help improve both the coverage and public profile of a station, these benefits come at a price. When a problem occurs at the transmitter site, personnel must often travel there without knowing the nature of the problem nor for example, which spare parts to bring. A comprehensive remote monitoring system can tell them exactly what has happened and save valuable time.
|
 |
|
Click to enlarge |
MAC units have been designed and tested to withstand harsh RF environments. Immediate access to real-time site information, like transmitter status, antenna VSWR, audio/video levels and presence, mains and auxiliary power levels, temperature, tower lighting, fire alarm and building security status can be just a mouse click away.
In order to ensure transmission sites are continuously up-and-running, Davicom MAC systems provide automation with decision-making features and commands that go well beyond conventional telemetry systems. They can automatically perform AM antenna day/night pattern changes, program chain switching, transmitter changes, generator exercising, battery testing, etc.
|
Upon an RF failure, they can place the standby transmitter on-air to restore the signal, and alert on-call personnel. Engineering staff can then diagnose the problem from the event history log and, using remote measurements, decide on the appropriate course of action.
Multilevel alarms can be sent by the MAC to the Network Operations Centre (NOC) and other resources by e-mail, phone (voice or SMS), pager, SNMP traps, fax, modem, or to the MacNet multi-site alarm management software. The MAC's voice response system can also talk to personnel over the phone or voice pager. Multiple alarm-call lists allow the MAC to contact different groups depending on the event, or the day and time. Individual signal and status conditions can be qualified by time delays and hysteresis to prevent annoyance alarms.
MAC units can be interrogated by PC using the MacComm software, with a Web browser or SNMP manager, or by telephone to check signals and status, monitor live audio feeds and execute commands. Blackberry®, iPhone® and other smart phones and devices can also be used to monitor and control a site over the mobile Internet and from WiFi hotspots. The MAC's reach-through serial ports can be used to access and control other on-site ancillary equipment. The MAC can even ping site equipment through its local IP port and monitor for dial tone on the telephone line.
MAC units are FCC, Industry Canada and CE certified. They are also
RoHS/WEEE compliant. The management system governing the manufacture of this product is ISO9001:2000 certified.
See the benefits of owning Davicom MAC units
All MAC units have the following features:
|
- 128 internal event timers |
- Alarms via E-Mail with HTML or XML file attachments |
|
- USB device port on front panel |
- Alarms via SMS |
|
- USB host port on back panel |
- Transmission to multiple Pagers |
|
- Secure IP over Ethernet or Internet |
- Vocal descriptions from 400-word vocabulary |
|
- Automatic action on conditions or events |
- Sync to NTP & ACTS servers |
|
- Voice response/DTMF over phone |
- Battery Discharge Test |
|
- Bilingual voice |
- 333 MHz Processor Speed |
|
- Bilingual screens |
- 2 MB Internal Battery Backed RAM |
|
- Can accommodate up to 6 modems (1 internal) |
- PSTN Caller ID placed in log |
|
- FAX transmission capability |
- RF immunity to 10V/m |
|
|
- Electro Static Discharge immunity to 12kV |
|
- Compatible with MacNet NOC software |
- User configurable screens |
|
- Integrated Web Server |
- Multiple workspaces |
|
- 100 ms sampling interval on inputs |
- Operates from 12 VDC supply |
|
- Individual Relay pulsing to 0.1s resolution |
- Automatic Day-Night settings from Latitude & Longitude |
|
- 16 alarm-call lists with 10 recipients per list |
- Logging to: System log, Custom log, EAS log, Data log |
|
- Configurable delays on individual alarms |
- Automatic VSWR calculation |
|
- Hysteresis on metering inputs |
- Linearization of sensor inputs |
|
- Local ping of 32 network devices |
- Activity Timer on Status Inputs |
|
- 4 Multiple simultaneous users |
- No moving parts (Cooling Fan or HDD) |
|
- 16 Math Functions |
- Modbus I/O expansion capability in TCP or RTU modes |
| - Automatic detection of PSTN dial-tone |
- Special IP commands between remote MAC units |
| - PPP (Point to Point Protocol) support |
- Expansion with MEXM |
|
|
Choose the MAC unit that best fits your needs:
PRODUCT FEATURE COMPARISON TABLE
| Feature |
MicroMAC |
MiniMAC2 |
MAC208 |
MAC216 |
| Metering Inputs |
8 |
8 |
8 |
16 |
|
Status Inputs |
8 |
16 |
16 |
32 |
| Internal SPDT 60W Relays |
8 |
8 |
16 |
32 |
| Range of metering inputs |
0-5 VDC |
±2.5, ±10, ±20V |
±2.5, ±10, ±20V |
±2.5, ±10, ±20V |
| 4-20mA mode on metering inputs |
NO |
YES |
YES |
YES |
| Audio detection on metering inputs |
NO |
YES |
High precision True-RMS option |
High precision True-RMS option |
| AUX. Serial Ports (for tunneling to other devices) |
0* |
1* |
4* |
8* |
| RS-232 port on front panel |
NO |
YES |
YES |
YES |
| Ethernet ports |
1 |
2 |
2 |
2 |
| SNMP agent built-in |
NO |
V1, V2C |
V1, V2C |
V1, V2C |
| SNMP manager built-in |
NO |
96 GETs, 96 SETs and 96 traps |
96 GETs, 96 SETs and 96 traps |
96 GETs, 96 SETs and 96 traps |
| Real Time Clock (RTC) |
STD stability |
TCXO, Hi Stab |
TCXO, Hi Stab |
TCXO, Hi Stab |
| Internal Flash ROM |
32MB |
64MB |
64MB |
64MB |
| Internal RAM |
32MB |
96MB |
96MB |
96MB |
| Audio port monitoring over dial-up |
1 |
2 |
4 |
8 |
| Audio port monitoring over IP streaming |
0 |
2 |
4 |
8 |
| Front-panel buttons |
Local |
Pause/Local |
Pause/Local |
Pause/Local |
| Operating temperature range |
32 to 122°F
(0 to 50°C) |
32 to 122°F
(0 to 50°C) |
32 to 122°F
(0 to 50°C) |
32 to 122°F
(0 to 50°C) |
| Optional extended temperature range |
-40 to 158°F
(-40 to 70°C) |
-40 to 158°F
(-40 to 70°C) |
-40 to 158°F
(-40 to 70°C) |
-40 to 158°F
(-40 to 70°C) |
| Rack space |
1 RU, half width |
1 RU |
2 RU |
2 RU |
| Dimensions |
(W x H x D)
8 1/2 X 1 3/4 X 12 in
21.6 X 4.4 X 30.5 cm |
(W x H x D)
19 X 1 3/4 X 12 in
48.3 X 4.4 X 30.5 cm |
(W x H x D)
19 X 3 1/2 X 12 in
48.3 X 8.9 X 30.5 cm |
(W x H x D)
19 X 3 1/2 X 12 in
48.3 X 8.9 X 30.5 cm |
| Weight (unit only) |
4 lbs
(1.8 kg) |
6 lbs
(2.7 kg) |
7 lbs
(3.2 kg) |
8 lbs
(3.6 kg) |
* up to 8 optional USB to serial adapters can be added for tunneling to other devices.
MAC2 Products
Typical Current Requirements (in mA) at 12VDC supply
|
Product |
Idle |
With USB Key |
Startup |
MAX* |
|
MAC208-1 |
592 |
636 |
1204 |
900 |
|
MAC208-2 |
510 |
556 |
1132 |
829 |
|
MAC216-1 |
720 |
752 |
1336 |
1265 |
|
MAC216-2 |
640 |
688 |
1256 |
1188 |
|
MiniMAC2-1 |
714 |
764 |
1320 |
882 |
|
MiniMAC2-2 |
626 |
660 |
1210 |
764 |
|
MicroMAC-1 |
748 |
836 |
832 |
928 |
|
MicroMAC-2 |
655 |
732 |
760 |
852 |
|
MicroMAC-1 ** |
460 |
512 |
1224 |
640 |
|
MicroMAC-2 ** |
420 |
464 |
1176 |
592 |
* All relays energized with simultaneaous IP transfer and Flash Memory programming
** With optional Switching Regulators
Note: Comlab reserves the right to change the design and specifications without notice.
See what's new in the latest releases
|
MAC Systems Brochures : |
|
|
FILE SIZE |
| MAC2 / MiniMAC2 / MicroMAC |
|
1.7 MB |
View PDF»  |
| MEXM-1 |
|
1.2 MB |
|